Skip to main content

OptiPlate 384-well, white opaque, case of 50

384-well microplate for use in time-resolved fluorescence, luminescence, Alpha, and radiometric assays. This OptiPlate™ is white and made of polystyrene.

For research use only. Not for use in diagnostic procedures.

Feature Specification
Surface Treatment Untreated
Color White
Detection Modality Alpha
Luminescence
Radiometric
Time-Resolved Fluorescence (TRF & TR-FRET)
Lids Included? No
Material Polystyrene
Sterility Non-Sterile
Plate Format 384 wells
Well Shape Flat-bottom
Well Volume 105 µL
Working Volume 24 - 90 µL

384-well microplate for use in time-resolved fluorescence, luminescence, Alpha, and radiometric assays. This OptiPlate™ is white and made of polystyrene.

For research use only. Not for use in diagnostic procedures.

Overview

OptiPlate™ is one of most versatile microplates offered by Revvity, used in many different applications, assays, and instruments. optimized well design and high quality plastics provides low background and crosstalk.

OptiPlates are uniquely engineered to be same height 96-, 384-, and 1536-well plates, and with extraordinary well flatness ease in automation.

Leveraging years of assay and instrument experience in plate detection, Revvity designs better microplates better performance that guarantees better results all Revvity applications.

Packaging Notes:
  • Cases of 50 are packaged as 2 sleeves of 25 plates each. Each sleeve as 5 wraps with 5 plates.
  • Cases of 100 are packaged as 4 sleeves of 25 plates each.
  • Cases of 200 are packaged as 8 sleeves of 25 plates each. Each sleeve as 5 wraps with 5 plates.

Additional product information

Well plate dimensions

Well format: 384-well

Description Specification
Number of rows 16
Number of columns 24
Well volume 105 µL
Recommended working volume 24 µL – 90 µL
Height (mm) 14.35
Length (mm) 127.76
Width (mm) 85.47
Well diameter (mm) 3.65
Well depth (mm) 10.4
A1 to top offset (mm) 9
A1 to side offset (mm) 12.1
Well-to-well spacing (mm) 4.5

 

 

Specifications

Color
White
Plate Format
384 wells
Well Shape
Flat-bottom
Well Volume
105 µL
Working Volume
24 - 90 µL
Application
Radiometric
Research
Automation Compatible
Yes
Brand
OptiPlate
Detection Modality
Alpha
Luminescence
Radiometric
Time-Resolved Fluorescence (TRF & TR-FRET)
Format
Microplates
Lids Included?
No
Material
Polystyrene
Shipping Conditions
Shipped Ambient
Sterility
Non-Sterile
Surface Treatment
Untreated
Unit Size
Case of 50

Resources

Are you looking for resources, click on the resource type to explore further.

13-16 of 16 Resources
Application Note Icon
Application Note
Measuring Performance of an Automated and Miniaturized LANCE Ultra cAMP Assay for the Gi-coupled 5-HT1A Receptor- a Comparative Study

In this note we describe the miniaturization of a LANCE Ultra cAMP assay from 384-to 1,536-well plate format for the...

Application Note Icon
Application Note
Quantify low abundant mIL-17A homodimer in mouse serum and plasma

Measuring low levels of biomarkers in complex biological samples such as serum and plasma is always a challenge. This is further...

Application Note Icon
Application Note
Using AlphaLISA biomarker kits to assess effects of PBMC-conditioned media on 3D and 2D cell culture models of breast cancer

Various cytokines are secreted during an active immune response that can have modulatory effects on target cell populations...

Application Note Icon
Application Note
Utilization of AlphaLISA technology to accurately detect asthma biomarkers in human serum

Asthma is a chronic inflammatory disease that affects millions of people around the world. The detection of specific asthma...

SDS, COAs, Manuals and more

Are you looking for technical documents related to the product? We have categorized them in dedicated sections below. Explore now.

Technical data sheet
+ Show more
Scroll Icon