The Omni Bead Ruptor Elite is an advanced and easy-to-use bead mill homogenizer. It is specifically designed for grinding, lysing, and homogenizing biological samples prior to molecular extraction. It is designed with a unique carriage motion to ensure that the intra-tube bead movement reduces swirling and results in high-impact bead milling. The increased power of the Bead Ruptor Elite decreases processing time and reduces sample heating to maximize sample preparation efficiency.
All Bead Ruptor Tube Carriages Sold Separately.
For research use only. Not for use in diagnostic procedures.
Lyse tough samples in seconds with The Bead Ruptor Elite.
The Bead Ruptor Elite is designed with a unique carriage motion to ensure that the intra-tube bead movement reduces swirling and results in high-impact bead milling. The increased power of the Bead Ruptor Elite decreases processing time and reduces sample heating to maximize sample preparation efficiency.
The Bead Ruptor Elite unique tube carriage motion coupled with sample-specific bead beating materials ensure that a thorough homogenate is achieved regardless of the sample type. The high lysing efficiency of the Bead Ruptor Elite results in a increase in nucleic acid, protein and small molecules yields in the downstream assay.
Wide range of bead kits for any sample type
We offer users a range of flexibility with a range of bead beating tubes and lysing matrices to support homogenization of any sample type.
When comparing several commercially available bead mill homogenizers based on maceration level, nucleic acid quality, quantity, amplification, and DNA shearing to determine which instruments were effective for their sample type, the authors’ wrote:
"The Bead Ruptor 24 Elite had the highest overall score when disrupting a single, uninfected adult Amblyomma americanum (Linnaeus) (Ixodida: Ixodidae) and performed well in follow-on tests…."1
The authors' continued to note,
“Upon receiving the highest score on the evaluation matrix, the Bead Ruptor 24 Elite was further tested to determine whether it could consistently disrupt a tick body enough to release detectable quantity of pathogen…. In the present study, the tested traditional bead homogenizer, the Bead Ruptor 24 [Elite], seemed to perform the best overall.”1
Omni Bead Ruptor Elite homogenizer features
References:
Depth |
43.2 cm
|
---|---|
Height |
33.0 cm
|
Voltage |
110V Japan
|
Weight |
29.0 kg
|
Width |
38.1 cm
|
Accreditations |
CE
|
---|---|
Cycles/Programs |
1 to 10 Cycles 99 Programs
|
Interface |
Touchscreen
|
Sample Volume |
25 µL to 50 mL
|
Special Ordering Information |
Bead Ruptor Drive Unit (19-042J), Universal Finger Plate (19-370) and User Manual.
|
Speed |
0.8 – 8 m/s in increments of 0.15 m/s
|
Timer |
1 second to 9:59 minutes
|
Warranty |
1 Year
|
Are you looking for resources, click on the resource type to explore further.
Reliable extraction of viral RNA from tissue samples is an important step in viral detection for research studies. The Omni Bead...
The need for better profiling is clear, and technological advances are making it possible to optimize clinical trials and...
Technological advancements have rapidly boosted the adoption of single-cell sequencing experiments – by increasing the number of...
Are you looking for technical documents related to the product? We have categorized them in dedicated sections below. Explore now.
We are here to answer your questions.