Omni Bead Ruptor Elite bead mill homogenizer

The Omni Bead Ruptor Elite is an advanced and easy-to-use bead mill homogenizer. It is specifically designed for grinding, lysing, and homogenizing biological samples prior to molecular extraction. It is designed with a unique carriage motion to ensure that the intra-tube bead movement reduces swirling and results in high-impact bead milling. The increased power of the Bead Ruptor Elite decreases processing time and reduces sample heating to maximize sample preparation efficiency.

All Bead Ruptor Tube Carriages Sold Separately.

For research use only. Not for use in diagnostic procedures.

Product Variants
Voltage: 115-230V
Part #:
19-042E
Voltage: 110V Japan
Part #:
19-042J

Overview

Lyse tough samples in seconds with The Bead Ruptor Elite.

  • Wide range of accessories for any sample size - 24 x 0.5 mL, 24 x 1.5 mL, 24 or 48 x 2 mL, 12 x 7 mL, 12 x 15 mL, 6 x 30 mL, 3 x 50 mL.
  • Most powerful bead mill on the market – homogenize the most challenging samples
  • New touch screen interface. Sample Preparation at your fingertips.
  • Optimate™ sample prep software
  • No cool down required between runs: process hundreds of samples per day
  • Convenient front loading design, 99 programmable memory settings, and multilingual user interface
  • Features an integrated lid lock to prevent lid opening during operation
  • A robust homogenizer for preparing samples when extracting DNA, RNA, proteins, and small molecules
  • Optimized tube motion ensures high performance

The Bead Ruptor Elite is designed with a unique carriage motion to ensure that the intra-tube bead movement reduces swirling and results in high-impact bead milling. The increased power of the Bead Ruptor Elite decreases processing time and reduces sample heating to maximize sample preparation efficiency.

The Bead Ruptor Elite unique tube carriage motion coupled with sample-specific bead beating materials ensure that a thorough homogenate is achieved regardless of the sample type. The high lysing efficiency of the Bead Ruptor Elite results in a increase in nucleic acid, protein and small molecules yields in the downstream assay.

Wide range of bead kits for any sample type.

We offer users a range of flexibility with a range of bead beating tubes and lysing matrices to support homogenization of any sample type.

Additional product information

When comparing several commercially available bead mill homogenizers based on maceration level, nucleic acid quality, quantity, amplification, and DNA shearing to determine which instruments were effective for their sample type, the authors’ wrote:

"The Bead Ruptor 24 Elite had the highest overall score when disrupting a single, uninfected adult Amblyomma americanum (Linnaeus) (Ixodida: Ixodidae) and performed well in follow-on tests…."1

The authors' continued to note,

“Upon receiving the highest score on the evaluation matrix, the Bead Ruptor 24 Elite was further tested to determine whether it could consistently disrupt a tick body enough to release detectable quantity of pathogen…. In the present study, the tested traditional bead homogenizer, the Bead Ruptor 24 [Elite], seemed to perform the best overall.”1

Omni Bead Ruptor Elite homogenizer features

References:

  • Amanda M Jones, Marshall T Van de Wyngaerde, Erika T Machtinger, Edwin G Rajotte, Thomas C Baker, Choice of Laboratory Tissue Homogenizers Matters When Recovering Nucleic Acid From Medically Important Ticks, Journal of Medical Entomology, Volume 57, Issue 4, July 2020, Pages 1221–1227, https://doi.org/10.1093/jme/tjaa006

Specifications

Depth
43.2 cm
Height
33.0 cm
Voltage
115-230V
Weight
29.0 kg
Width
38.1 cm
Accreditations
CE
Cycles/Programs
1 to 10 Cycles 99 Programs
Interface
Touchscreen
Sample Volume
25 µL to 50 mL
Special Ordering Information
Bead Ruptor Drive Unit (19-042E), Universal Finger Plate (19-370) and User Manual.
Speed
0.8 – 8 m/s in increments of 0.15 m/s
Timer
1 second to 9:59 minutes
Warranty
1 Year

Video gallery

Resources

Are you looking for resources, click on the resource type to explore further.

37-42 of 62 Resources
Application Note Icon
Application Note
Nucleic acid extraction from liver tissue: An integrated solution

The success of sensitive downstream genomic applications such as qPCR depend on robust and reliable upstream sample preparation...

Application Note Icon
Application Note
Nucleic acid extraction from Mus musculus tissues using the Omni Bead Ruptor Elite bead mill homogenizer and stainless-steel lysing/grinding tubes

In biomedical research, the ability to reliably extract DNA and RNA from fresh tissue samples is important for molecular...

Application Note Icon
Application Note
Nucleic acid recovery from multiple tissues with scalable throughput utilizing the KingFisher Flex and Omni Bead Ruptor Elite bead mill homogenizer

In this study, the Omni Bead Ruptor Elite homogenizer was integrated into a semi-automated workflow for high-throughput nucleic...

Application Note Icon
Application Note
Pesticide detection in food produce through bead mill homogenization and QuEChERS extraction

The QuEChERS method, a solvent extraction technique introduced in 2003, is widely used for the extraction of multiple pesticides...

Poster Icon
Scientific Poster
Pre-clinical animal tissue homogenization poster Omni Bead Ruptor Elite
Application Note Icon
Application Note
Protein extraction efficiency of bead mill homogenizers and total and phosphorylated protein detection by HTRF immunoassay

Protein extraction techniques from organs, tissues, and cells are critical in biomedical and pre-clinical research, such as in...

SDS, COAs, Manuals and more

Are you looking for technical documents related to the product? We have categorized them in dedicated sections below. Explore now.

IFUs, Manuals & more
Scroll Icon