Test Code | D5234 |
---|---|
Test Summary |
This assay detects copy number changes in the MLH1 and MSH2 genes, which are associated with Lynch syndrome. |
Turn Around Time | 12 days |
Acceptable Sample Types | DNA, Isolated , Dried Blood Spots , Saliva , Whole Blood (EDTA) |
Acceptable Billing Types | Institutional Billing , Self (patient) Payment |
NY Approved | No |
CPT Codes** | 81294(x1), 81297(x1) |
Multiplex Ligation-Dependent Probe Amplification (MLPA) detects the deletion and duplication of single and multiple exons within a given gene (PMID: 20938835). It is a semi-quantitative technique to determine relative copy number using a multiplex PCR-based reaction. Only hybridized and ligated adjacent probe oligonucleotides are amplified by PCR, thus specific for the sequence of interest. This test involves copy number analysis of the MLH1 and MSH2 gene.
Lynch syndrome (LS, MIM# 120435; formerly known as HNPCC, Hereditary Nonpolyposis Colorectal Cancer) is the most common heritable colorectal carcinoma (CRC) syndrome and is responsible for 2% to 4% of all CRC cases in the Western world. Heterozygous germline mutations in one of the mismatch repair (MMR) genes MSH2 (MIM# 609309), MLH1 (MIM# 120436), MSH6 (MIM# 600678), or PMS2 (MIM# 600259) are responsible for Lynch syndrome (PMID: 20301390). Another cause of Lynch syndrome is the deletion of the 3’ part of EPCAM, leading to constitutional epigenetic silencing of the downstream MSH2 gene. The estimated contribution of the different genes to Lynch syndrome is 15-40% for MLH1, 20-40% for MSH2, 12-35% for MSH6, 5-25% for PMS2 and <10% for EPCAM (PMID: 20301390).
Defects in the MLH1 and MSH2 genes include deletions and duplications of complete exons, which are usually missed by standard sequence analysis. The MLPA technique can detect most of these deletions and duplications and therefore complements sequence analysis of the MLH1 and MSH2 genes.
MLPA-based assay for detecting deletions/duplications in the MLH1 and MSH2 gene. The MRC-Holland reagent kits and the Applied Biosystem 3730xl DNA Analyzer instrument generate fragment analysis data.
Collection | Required DNA Quantity by Test Type*:
|
---|---|
Sample Condition | * Required DNA Quality: High molecular weight DNA (>12kb). A260/A280 reading should be ≥ 1.8. A260/230 a ratio range of 1.8 to 2.2. Contact the laboratory for specific amounts if total ng cannot be met. |
Shipping | Ship overnight at ambient temperature. |
Special Sample Instructions |
|
Collection Container(s) | EDTA (purple top) |
---|---|
Collection | Infants (< 2-years): 2 to 3 mL; Children (>2-years): 3 to 5 mL; Older children and adults: Minimum 5mL. The blood tube should be inverted several times immediately after blood collection to prevent coagulation. |
Sample Condition | Store at ambient temperature. Do not refrigerate or freeze. |
Shipping | Ship overnight at ambient temperature ensuring receipt within 5-days of collection. |
Special Sample Instructions | Clotted or hemolyzed samples are not accepted. |
Collection Container(s) | Oragene™ Saliva Collection Kit or ORAcollect-Dx kit |
---|---|
Collection | Collect saliva on an Oragene™ Saliva Collection Kit ORAcollect-Dx kit according to the manufacturer's instructions. |
Sample Condition | Store at ambient temperature. Do not refrigerate or freeze. |
Shipping | Ship overnight at ambient temperature. |
Special Sample Instructions | Please contact Revvity Omics to request the saliva collection kit for patients who cannot provide a blood sample as whole blood is the preferred sample. Testing using Saliva swabs is currently not available for customers in India. Contact the Revvity Omics laboratory for more information. |
Collection Container(s) | Dried blood spot card |
---|---|
Collection | Follow kit instructions. Briefly, allow blood to saturate the card until indicated areas are filled and blood has soaked through the card. Air dry the card at ambient temperature for at least 3 hours.
|
Sample Condition | Follow the instructions provided with the collection set. Store the dried blood at ambient temperature for up to two days. If the specimen cannot be sent as soon as it is dry, the filter paper should be placed in a sealable plastic bag and stored in a refrigerator (≤ 8°C) or preferably in a freezer. |
Shipping | Follow kit instructions. Double bag and ship overnight at ambient temperature. |