CNV analysis utilizing low pass genome sequencing assay (8x) for the proband and 2 family members.
Test Code | D0901 |
---|---|
Test Summary |
CNV analysis utilizing low pass genome sequencing assay (8x) for the proband and 2 family members. |
Turn Around Time | 10 - 12 days |
Acceptable Sample Types | DNA, Isolated , Dried Blood Spots , Saliva , Whole Blood (EDTA) |
Acceptable Billing Types | Institutional Billing , Self (patient) Payment |
NY Approved | No |
CPT Codes** | 81349(x3) |
This test detects large copy number changes (CNVs) greater than or equal to 25kb throughout the genome and reliably detects chromosome uniparental disomy. Testing is performed utilizing low pass genome sequencing (8x).
Direct sequencing of genomic DNA was performed using 2X150bp reads on Illumina next generation sequencing (NGS) systems at a mean coverage of 10X in the target region. Alignment to the human reference genome (GRCh37) was performed and copy number variant (CNV) calls made using the NxClinical software v6.1 (BioDiscovery, Inc., El Segundo, CA). CNVs meeting internal quality assessment guidelines may be confirmed by alternative assays at a director’s discretion. This assay cannot detect CNVs in regions of the genome that are not amenable to NGS and does not interrogate CNVs in mitochondrial DNA. CNVs involving genes with pseudogenes and pseudoexons may not be reliably detected or reported. This assay will not detect tandem repeats, balanced alterations (reciprocal translocations, Robertsonian translocations, inversions, and balanced insertions), point mutations, methylation abnormalities, triploidy, and genomic imbalances in segmentally duplicated regions. This assay is not designed to detect mosaicism; possible cases of mosaicism may be investigated at the discretion of the laboratory director. This assay may not be able to detect small pathogenic CNVs within an exon, small intragenic deletions or duplications, and complex rearrangements. This assay may not be able to accurately quantify copy number state equal to or greater than 4 (triplication or above). Due to high sequence similarity between the pseudoautosomal regions (PARs) of the X and Y chromosomes, CNVs located within these genomic segments (chrX:60000-2699520; chrX:154930289-155260560; chrY:10000-2649520; chrY:59033286-59363566) cannot be accurately localized to either the X or Y chromosome in male individuals.
Collection Container(s) |
EDTA (purple top) |
---|---|
Collection |
Infants (< 2-years): 2 to 3 mL; Children (>2-years): 3 to 5 mL; Older children and adults: Minimum 5mL. The blood tube should be inverted several times immediately after blood collection to prevent coagulation. |
Sample Condition |
Store at ambient temperature. Do not refrigerate or freeze. |
Shipping |
Ship overnight at ambient temperature ensuring receipt within 5-days of collection. |
SPECIAL SAMPLE INSTRUCTIONS |
Clotted or hemolyzed samples are not accepted. |
Collection Container(s) |
Oragene™ Saliva Collection Kit or ORAcollect-Dx kit |
---|---|
Collection |
Collect saliva on an Oragene™ Saliva Collection Kit ORAcollect-Dx kit according to the manufacturer's instructions. |
Sample Condition |
Store at ambient temperature. Do not refrigerate or freeze. |
Shipping |
Ship overnight at ambient temperature. |
SPECIAL SAMPLE INSTRUCTIONS |
Please contact Revvity Omics to request the saliva collection kit for patients who cannot provide a blood sample as whole blood is the preferred sample. Testing using Saliva swabs is currently not available for customers in India. Contact the Revvity Omics laboratory for more information. |
Collection Container(s) |
Dried blood spot card |
---|---|
Collection |
Follow kit instructions. Briefly, allow blood to saturate the card until indicated areas are filled and blood has soaked through the card. Air dry the card at ambient temperature for at least 3 hours.
|
Sample Condition |
Follow the instructions provided with the collection set. Store the dried blood at ambient temperature for up to two days. If the specimen cannot be sent as soon as it is dry, the filter paper should be placed in a sealable plastic bag and stored in a refrigerator (≤ 8°C) or preferably in a freezer. |
Shipping |
Follow kit instructions. Double bag and ship overnight at ambient temperature. |
Collection |
Required DNA Quantity by Test Type*:
|
---|---|
Sample Condition |
* Required DNA Quality: High molecular weight DNA (>12kb). A260/A280 reading should be ≥ 1.8. A260/230 a ratio range of 1.8 to 2.2. Contact the laboratory for specific amounts if total ng cannot be met. |
Shipping |
Ship overnight at ambient temperature. |
SPECIAL SAMPLE INSTRUCTIONS |
|
Select the correct test for your patient, and download and fill out the Clinical Genomics test requisition form.
Obtain a sample for testing from the patient using one of the provided Revvity Omics test packs.
Send samples and all required forms back to Revvity for processing using pre-paid shipping label.
We are here to answer your questions.