The Cellaca™ PLX system with Matrix analysis software and dedicated reagents and consumables provides a benchtop solution for accurate measurements of small sample volumes to easily perform rapid subpopulation analysis for downstream processing.
For research use only. Not for use in diagnostic procedures.
The Cellaca PLX system with Matrix analysis software and dedicated reagents and consumables provides a benchtop solution for accurate measurements of small sample volumes to easily perform rapid subpopulation analysis for downstream processing.
Multiplexing Made Easy
The Cellaca PLX image cytometry system is easy to use, performing simple yet sensitive cell counts, viability readouts, and multiplex analysis in seconds.
Small Sample Volume
The sample-efficient Cellaca PLX requires between 15 – 50 uL per single sample analysis. That’s 10-30 times less sample volume required per test, compared to a flow cytometer.
Speed with Sensitivity
The time to downstream processing is shortened by multiplexing with four channels with viability readouts at one minute per sample.
Optimized Assays and Kits
Our simple-to-use, mix, incubate, wash, and read reagent kits provide immunophenotyping plus viability multiplexing assays using disposable, low fluorescence consumables.
User-Friendly Software
Optimized protocols streamline surface marker staining, vitality, and apoptosis analysis with step-by-step methodologies and customizable result presentations.
Low Auto-Fluorescent Consumables
Allow for accurate surface marker detection.
Hardware, Instruments, and System Capabilities
The Cellaca PLX’s ability to consistently image, de-cluster, and report cell counts, viability, concentration, and phenotyping data makes it a versatile instrument during every stage of cell line development. The Cellaca PLX allows labs to shorten the time to downstream processing by multiplexing with up to four channels to obtain critical viability readouts at one minute per sample with no warm-up time. The cell population data can then be viewed as a histogram, scatter plot, dot plot, or contour plot for easy data viewing and analysis.
Whether using it as a complementary method for additional data or as the first stop before starting downstream assays, image cytometry can save laboratories time and prevent excessive sample loss. With this output speed, researchers can quickly perform cell purity checks at the bench and then easily continue with downstream assays without waiting for a flow cytometer. By performing multiplexing assays at the bench, laboratories can reduce the reliance on a busy flow core facility, saving flow cytometry for more complicated or detailed assays.
Expert Support for Assay Development
On-site, remote, and hybrid training are available to assist with initial setup and continued assay support for improved workflows.
Remote and Field Serviceability
Calibration-free instrumentation with minimal routine maintenance. No clogging or liquid waste stream.
Automation Ready
Compatible with robotic integration and automated liquid handling systems.
21 CFR Part 11 Ready
Built-in assays with optimized settings for over 400 individual cell types.
Configurable data and calculation reports with graphs, images, charts, and tables for ease of information sharing.
Low Auto-Fluorescent Consumables
Cellaca PLX consumable slides provide a safe and self-contained environment for the sample which then does not require a decontamination procedure of the instrument at the end of each run. The slide holder, which is included with the instrument, can accommodate 4 slides or 8 samples per experimental run.
Cellaca PLX Optimized Assay Reagents and Kits
The Cellaca PLX system provides flow-like data with simple-to-use, mix, incubate, wash, and read reagent kits that provide immunophenotyping plus cell counts and viability multiplexing assays using disposable, low fluorescence consumables. Quickly perform cell counts, concentration, purity checks, and viability at the bench with Cellaca PLX immunophenotyping kits which combine CD3, CD4, and CD8 surface marker detection with cell viability in a single multiplex assay.
Available assay kits include:
Cellaca PLX Applications
With the Cellaca PLX Platform, you can:
Brand |
Cellaca
|
---|---|
Unit Size |
1 Each
|
Are you looking for resources, click on the resource type to explore further.
One of the most promising fields in cancer research is immunotherapy – manipulating the existing immune system to specifically...
The hemacytometer is an integral part of all cell-based research, and yet sources of error inherent in its design and utilization...
In this case study, we explore how Mr. Julian Reading, Senior Manager of Flow Cytometry at the Allen Institute of Immunology in...
Functional genomic screening (FGS) is a powerful tool for researchers and scientists to explore the intricate world of genomics...
The importance of cell counting has increased significantly in the last decade due to the major advances in the fields of cell and...
Are you looking for technical documents related to the product? We have categorized them in dedicated sections below. Explore now.
We are here to answer your questions.