Skip to main content

NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit

The NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit is designed for the preparation of multiplexed amplicon libraries that span the hypervariable domains three through four (V3 and V4) of microbial 16S ribosomal RNA (rRNA) genes. These libraries are compatible with paired-end sequencing on the Illumina® and Element Biosciences® sequencing platforms.

There are two main steps involved in 16S V3 – V4 amplicon processing: an initial PCR amplification using customized PCR primers that target the V3 and V4 domains, and a subsequent PCR amplification that integrates relevant flow cell binding domains and unique 12 base pair sample indices. The limited number of cleanup steps ensures maximum recovery of amplicons for downstream sequencing.

For research use only. Not for use in diagnostic procedures.

Feature Specification
Automation Compatible Yes
Product Group 16S amplicon-seq

The NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit is designed for the preparation of multiplexed amplicon libraries that span the hypervariable domains three through four (V3 and V4) of microbial 16S ribosomal RNA (rRNA) genes. These libraries are compatible with paired-end sequencing on the Illumina® and Element Biosciences® sequencing platforms.

There are two main steps involved in 16S V3 – V4 amplicon processing: an initial PCR amplification using customized PCR primers that target the V3 and V4 domains, and a subsequent PCR amplification that integrates relevant flow cell binding domains and unique 12 base pair sample indices. The limited number of cleanup steps ensures maximum recovery of amplicons for downstream sequencing.

For research use only. Not for use in diagnostic procedures.

Product Variants
Unit Size: 96 rxns
Analysis
Included
Barcodes
1 - 48
Part #:
NOVA-4204-03S
Unit Size: 192 rxns
Analysis
Included
Barcodes
1 - 96
Part #:
NOVA-4204-04S
Request More Information

Overview

  • Optimized protocol offers lower PCR bias and fewer off-target reads
  • Fast library prep protocol
  • Low input – As low as 1 ng of genomic DNA
  • Flexible barcode options
  • Automation protocols are now available for the Revvity Sciclone® NGSx Workstation to automate your 16S sequencing
  • Functionally tested on the Illumina® MiSeq® sequencer

Optimized 16S Protocol Offers Lower PCR Bias and Fewer Off-target Reads

The protocol incorporated in the NEXTFLEX 16S V3 – V4 Amplicon-Seq Kit offers better sequencing results than can be obtained using traditional 16S sequencing protocols. The incorporation of the second PCR step in the protocol for the addition of the sample-specific index reduces the number of off-target reads typically encountered during amplicon sequencing.

Increase 16S V3 – V4 throughput and reduce errors with automation

A NEXTFLEX® automation protocol is now available on the Sciclone NGSx workstations to help labs increase their throughput and reduce human errors. Automated versions of the NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep kits are available by request.

Analysis Powered by CosmosID HUB®

The NEXTFLEX 16S V3-V4 rRNA Amplicon-seq panels are now available bundled with access to CosmosID-HUB; an online software solution that enables fast and easy analysis of complex microbiome data. CosmosID-HUB gives scientists user-friendly access to version-controlled and validated 16S pipelines. The machine-learning powered software also enables rapid data interpretation through a comparative analysis software with features such as tables, heatmaps, bar charts, multiple Alpha & Beta Diversity indexes, abundance distribution plots, differential abundance testing, as well as comprehensive statistics between groups. Learn more about CosmosID-HUB.

Revvity 16S rRNA Analysis - Online Demonstration

Now you can schedule a one-on-one 30-minute online demonstration that will cover everything you need to know about the CosmosID-Hub® which is now available with Revvity’s NEXTFLEX™ 16S rRNA Amplicon-seq Kits. You will be able to see the analysis demonstrated and our experts will be able to answer any questions that you may have. Please choose a timeframe that suits you best and we will provide you a Microsoft Teams personal link to join when the time comes. We look forward to speaking with you.

Specifications

Analysis
Included
Automation Compatible
Yes
Barcodes
1 - 96
Product Group
16S amplicon-seq
Shipping Conditions
Shipped in Dry Ice
Unit Size
192 rxns

Resources

Are you looking for resources, click on the resource type to explore further.

1-4 of 4 Resources
Application Note Icon
Application Note
Automated homogenization and DNA extraction from murine GI tract tissue, cultures, and mock community for 16S sequencing

The success of sensitive downstream genomic applications such as qPCR depend on robust and reliable upstream sample preparation...

Flyer Icon
Flyer
End-to-end metagenomics solutions.

This flyer showcases Revvity's metagenomic portfolio as well as CosmosID's award winning analysis solution.

Infographic Icon
Infographic
Limitations in metagenomics analysis: a roadblock to discoveries

Metagenomics holds tremendous promise, yet it is not without its constraints, especially when it comes to the scarcity of powerful...

Flyer Icon
Flyer
Simplify your 16S library prep and analysis.

This flyer provides guidance on which NEXTFLEX metagenomic kit to use for microbial community profiling projects

Scroll Icon