Skip to main content

LANCE Ultra Human c-Myc Detection Kit, 10,000 Assay Points

The LANCE® Ultra c-Myc Detection Kit is designed for detection and quantitation of c-Myc peptide tag in buffered solution and cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.

Feature Specification
Application Protein-Protein Interaction
Dynamic Range 46.1- 300,000 nM
Limit of Detection 46.1 nM  
Limit of Quantification 235.8 nM  
Sample Volume 5 µL

The LANCE® Ultra c-Myc Detection Kit is designed for detection and quantitation of c-Myc peptide tag in buffered solution and cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.

Product Variants
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Request More Information

Overview

The LANCE Ultra c-Myc Detection Kit is designed for detection and quantitation of c-Myc peptide tag in buffered solution and cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.

  • No-wash steps, no separation steps
  • TR-FRET technology
  • Sensitive detection
  • High reproducibility
  • Faster time-to-results
  • Easy automation
  • 96-well, 384-well, and 1536-well formats

LANCE and LANCE (Lanthanide chelate excite) Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One antibody of interest is labeled with an acceptor fluorophore [ULight™ dye]. A “tracer” analyte is biotinylated and binds Streptavidin labeled with donor Eu-chelate. Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm. In the presence of sufficient non-biotinylated analyte this emission will be diminished.

The c-myc polypeptide tag is derived from the c-myc gene. The tag can be used during affinity chromatography and to separate wild-type protein from recombinant protein. The c-myc tag can be used in indirect detection assays for which there is no antibody for the target.

Specifications

Application
Protein-Protein Interaction
Automation Compatible
Yes
Brand
LANCE Ultra
Detection Modality
LANCE
Dynamic Range
46.1- 300,000 nM
Limit of Detection
46.1 nM  
Limit of Quantification
235.8 nM  
Product Group
Kit
Sample Volume
5 µL
Shipping Conditions
Shipped in Blue Ice
Target
c-Myc
Target Class
Binding Assay
Target Species
Human
Technology
TR-FRET
Therapeutic Area
Oncology
Unit Size
10,000 Assay Points