The Revvity LabChip Pico Protein reagent provides a fast and easy way to analyze protein samples between 14-200 kDa requiring sensitivity equivalent to Silver Stain levels. Protein detection for concentrations as low as 10 pg/ul, with a linear dynamic range of four orders of magnitude.
Reagent designed for 400 sample capacity. Protein Express LabChip is sold separately (P/N 760499, LabChip GXII and LabChip GXII touch HT); (P/N CLS138950 for LabChip GXII Touch 24).
For research use only. Not for use in diagnostic procedures.
Feature | Specification |
---|---|
Analytical Sensitivity | 0.1% of total protein |
Instrument Compatibility |
LabChip GXII Touch HT LabChip GX Touch LabChip GX Touch 24 |
Linear Concentration Range | Antibodies: 50 ng / mL to 500 µg / mL (4 logs), Other Protein: 10 ng/mL to 100 µg/mL (4 logs) |
Sample Volume | 1 µL |
Size Range | 14 - 200 kDa |
Sizing Precision RSD (CV) | ± 20% |
Sizing Resolution | ± 10% difference in molecular weight |
The Revvity LabChip Pico Protein reagent provides a fast and easy way to analyze protein samples between 14-200 kDa requiring sensitivity equivalent to Silver Stain levels. Protein detection for concentrations as low as 10 pg/ul, with a linear dynamic range of four orders of magnitude.
Reagent designed for 400 sample capacity. Protein Express LabChip is sold separately (P/N 760499, LabChip GXII and LabChip GXII touch HT); (P/N CLS138950 for LabChip GXII Touch 24).
For research use only. Not for use in diagnostic procedures.
Choose the LabChip Protein Pico Assay, a silver staining equivalent, for samples ranging in size from 14 to 200 kDa.
Specifications
Analytical Sensitivity |
0.1% of total protein
|
---|---|
Application |
Protein Analysis
|
Automation Compatible |
Yes
|
Instrument Compatibility |
LabChip GXII Touch HT
LabChip GX Touch
LabChip GX Touch 24
|
Linear Concentration Range |
Antibodies: 50 ng / mL to 500 µg / mL (4 logs), Other Protein: 10 ng/mL to 100 µg/mL (4 logs)
|
Sample Type |
Protein
|
Sample Volume |
1 µL
|
Size Range |
14 - 200 kDa
|
Sizing Precision RSD (CV) |
± 20%
|
Shipping Conditions |
Shipped in Dry Ice
|
Sizing Resolution |
± 10% difference in molecular weight
|
Storage Conditions |
4°C
|
Technology |
Microfluidic Electrophoresis
|
Throughput |
41 sec
|
Unit Size |
1 kit
|