Skip to main content

Hard Tissue Homogenizing Mix 2.8 mm Ceramic (50 mL Tubes) (50/pk)

Omni Bead Ruptor Elite bead mill homogenizer compatible bead beating tubes are pre-filled with an optimized amount of lysing matrix to provide efficient and robust sample homogenates.

Product features:

  • 50 mL Polypropylene screw cap tubes pre-filled with 2.8 mm ceramic beads
  • Max centrifuge speed of 5,000 x g
  • Max processing force of 6 m/s

For research use only. Not for use in diagnostic procedures.

Product Variant
Quantity: 50
Part #:
19-6508
Feature Specification
Application Tough and fibrous plant material, hard tissues, seeds and feed
Bead Type or Material Ceramic
Diameter 30.0 mm
Material Polypropylene Tube and Polyethylene Cap
Sample Volume 2 mL to 35 mL
Volume 50.0 mL
Length 115.0 mm
Maximum G Force 5,000 x g
Feature Specification
Application Tough and fibrous plant material, hard tissues, seeds and feed
Bead Type or Material Ceramic
Diameter 30.0 mm
Material Polypropylene Tube and Polyethylene Cap
Sample Volume 2 mL to 35 mL
Volume 50.0 mL
Length 115.0 mm
Maximum G Force 5,000 x g

Overview

Hard tissue homogenizing mix (50 mL Tubes)

Recommended for: tough and fibrous plant material, hard tissues, seeds and feed.

Specifications

Diameter
30.0 mm
Length
115.0 mm
Volume
50.0 mL
Accreditations
None
Application
Tough and fibrous plant material, hard tissues, seeds and feed
Bead Type or Material
Ceramic
Material
Polypropylene Tube and Polyethylene Cap
Maximum G Force
5,000 x g
Quantity
50
Sample Volume
2 mL to 35 mL
Temperature Range
-80 to 121 °C

Video gallery

Resources

Are you looking for resources, click on the resource type to explore further.

1-4 of 4 Resources
Application Note Icon
Application Note
Bead mill-based plant protein extraction efficiency is not dependent upon starting sample quantity

Bead mill homogenizers enable rapid and efficient lysis of biological materials, including plants via high-impact forces generated...

Application Note Icon
Application Note
Determination of pesticide recovery rates from spiked fruit and vegetables using QuEChERS extraction with bead mill homogenization

The comminution step in sample prep is critical for the effectiveness of the QuEChERS method, a type of dSPE, for the multiple...

Application Note Icon
Application Note
Pesticide detection in food produce through bead mill homogenization and QuEChERS extraction

The QuEChERS method, a solvent extraction technique introduced in 2003, is widely used for the extraction of multiple pesticides...

Application Note Icon
Application Note
Streamlining homogenization of confectionery treats

Food safety and determination of the quality of food products are key components within food testing. The detection and...

Scroll Icon